Guide · 3D force plates
3D force plates, explained with real data
A 3D force plate measures the push of the ground in all three directions, up, forward-back and sideways, and the three moments about them. From those six numbers come where the push acts (the centre of pressure) and how the foot twists against the floor (the free moment), hundreds or thousands of times a second.
In short
- Measures: the vertical push Fz, the forward-back push Fy, the sideways push Fx, and the moments Mx, My, Mz.
- Adds over a vertical-only plate: braking and propulsion, sideways push, turning, and a true centre of pressure when the push leans.
- Not needed when every answer comes from the vertical push, as for most jump heights.
- Check before buying: which components are measured, crosstalk, natural frequency as installed, sampling with all plates running, one clock, raw data.
Watch the six numbers move
Three real recordings from open research data, played on a plate. The dark arrow is the push of the ground on the person, its parts are drawn in colour, and the green line is where it acted. Switch on the vertical-only view to see what a plate that weighs only up and down would report.
Drag the drawing to turn it, or use the arrow keys.
- Up
- Forward-back
- Sideways
- Whole push
- Place and its path
- Twist
- Where a vertical-only plate puts it
Pushes in body weights; place in centimetres from the middle of the plate, forward and to the right; twist in newton metres per kilogram of body mass.
Have a recording of your own? Open it in the free Analyzer.
What a 3D force plate is
A force plate is a stiff plate on sensors that reads the push between a person and the ground. A 3D force plate reads that push in all three directions. Most also read the three moments, which is why the same instrument is sold as a three-axis, triaxial, multi-axis, six-axis or six-component force plate, or as a force platform: different words, one idea. A vertical-only plate, also called a uniaxial or 1D plate, reads the up-and-down push alone.
What the plate reads is the ground reaction force. The floor pushes on the person exactly as hard as the person pushes on the floor, and besides gravity it is the only thing pushing on someone who stands, walks or jumps. So the plate’s reading is the sum of everything the body does to move its mass: every muscle and every swing of an arm, added into one push.
A force plate is not a pressure plate. A pressure plate or mat is a grid of small sensors that maps how the vertical load spreads under the foot. It shows the shape of the contact, which a force plate cannot. It does not measure the push along the floor or the twist, which a force plate does. The two answer different questions, and gait laboratories often use both.
The six numbers
| Number | Direction | What it shows in movement |
|---|---|---|
| Fz | Up | Body weight, landing and take-off, every jump and squat. The largest of the three pushes. |
| Fy | Forward and back | Braking and propulsion: how each step slows the body and speeds it up again. |
| Fx | Sideways | The push that steers: side steps, cuts, and the small sideways balance of every walking step. |
| Mx, My | About the two horizontal axes | Where on the plate the push acts: the centre of pressure. |
| Mz | About the vertical axis | The twist between foot and floor: the free moment. |
Names differ between makers. Some call the forward-back push Fx and others Fy, depending on how the plate is turned, and some count z downwards or give the person’s push on the plate instead of the plate’s push on the person. This page uses x to the right, y forward and z up, for the push of the ground on the person. Before you compare two files, check their axes, signs, units and the point the moments are taken about.
The centre of pressure
The centre of pressure is the point on the plate’s top where the whole push acts. A plate works it out from the moments: taken about the middle of the top, x = −My ÷ Fz and y = Mx ÷ Fz. It is not the centre of mass, and with two feet on one plate it lies between them, where neither foot is. It means something only while the vertical push is well above zero; at the very start and end of a contact it wanders.
The free moment
The free moment is the twist the foot puts into the floor about the vertical line through the centre of pressure: T = Mz − x·Fy + y·Fx. It is small, a few newton metres in a walking step, yet it is the only direct measure of how the ground turns the body. In distance running it is largest in the first half of contact (Holden and Cavanagh 1991); in walking it peaks as the body is pushed forward (Li et al. 2001).
What 3D adds over a vertical-only plate
A vertical-only plate measures the up-and-down push as well as a 3D plate does. What it misses shows up in four places, and the live view above shows all four.
Braking and propulsion
Every step brakes the body and then pushes it on. In the walking step above, the floor pushes back by up to 0.18 body weights and forward by up to 0.20 (our numbers from the open data). In sprinting, the direction of the push matters as much as its size: in one study, the share of the push that pointed forward, and how slowly that share fell as speed rose, went with 100 m performance, while the total push did not (Morin, Edouard and Samozino 2011).
Sideways push
Cutting, side steps and defending are sideways movements. In the cut above, the planted foot is braked by up to 0.80 body weights and pushed sideways by up to 0.59, under a vertical push close to 2. What a change of direction asks of the body depends on its angle and the speed of approach (Dos’Santos et al. 2018). A vertical-only plate sees only the vertical part.
Turning
Turning comes from horizontal pushes that do not line up, and from each foot’s twist. Before the half-turn jump above, one foot is pushed forward and the other back: together they turn the body before it leaves the ground. A vertical-only plate measures neither.
The true centre of pressure
A plate finds the centre of pressure from moments taken at the level of its sensors, below its surface. A 3D plate knows the push along the floor and corrects for that depth. A vertical-only plate cannot, so it reports the point where the line of the push crosses its sensors’ level: off by the depth times the lean, the horizontal push divided by the vertical. With sensors 4.8 cm under the top, that is about 1 cm at the walking step’s hardest braking and about 2 cm near toe-off (our calculation from the open data). In quiet standing, where the push stands almost upright, the error stays well under a millimetre. Switch on the vertical-only view above to watch it.
When vertical-only is enough
Jump height, vertical impulse, phase times, most isometric pulls and quiet-standing sway come from the vertical push, or need little else. If that is all you will ever measure, a vertical-only plate answers it. If braking, cutting, turning, gait or moments may matter before you would replace the plates, a 3D plate runs every vertical test as well. Our 1D vs 3D comparison walks through the decision.
How a 3D force plate works
Every force plate is a spring whose give is read. The top, stiff steel or aluminium, stands on sensors; under a person it gives by thousandths of a millimetre, and the sensors turn that give into a voltage that a converter counts many times a second.
Strain gauges or crystals
Two kinds of sensor dominate. Strain gauges are fine foil grids glued to metal that carries the load; their resistance changes as the metal stretches, and they hold a steady push, so a person can stand for minutes without the reading sinking. Piezoelectric sensors are crystals, usually quartz, that give off charge when squeezed. They are very stiff and follow fast changes well, but the charge slowly leaks away, so the reading of a steady push sinks with time and the plate is reset to zero just before each recording. Both are used in laboratories. The choice matters most for long standing recordings, where crystals drift, and for the fastest impacts, where stiffness counts.
Four sensors, six numbers
Most plates stand on four sensors near the corners, each reading up to three directions. The vertical push is the sum of the four vertical readings. The centre of pressure is their weighted average, the arithmetic Elftman used for his walking platform in 1938. The moments come from the differences between front and back, left and right, and the twist from the differences between the horizontal readings. A plate with more sensors uses the same arithmetic.
Keeping the three directions apart
The vertical push is many times larger than the horizontal ones, so the smallest leak between them shows. A plate that let 1 % of the vertical push into its sideways reading would add a hundredth of a body weight that was never there, a large share of the sideways push in the walking step above. Engineers call this crosstalk. It is kept small by the build, with sensors seated square under a stiff top, and by arithmetic: each plate is loaded with known forces at known places, and a calibration matrix turns its channels into the six numbers with the leaks taken out. A carefully built high-speed force treadmill leaked 0.16 to 0.20 % (Bundle, Powell and Ryan 2015). Recalibrating plates where they stand cut their centre of pressure errors by 63 % in one study (Collins et al. 2009): the floor is part of the plate.
Fast enough to follow, steady enough to hold
Strike a plate and its top rings, at its natural frequency. The rule instrument builders use: it should ring at least ten times faster than the fastest change you want to follow (Lentink, Haselsteiner and Ingersoll 2015). Anything that adds mass or softness lowers it: a treadmill on top, a soft floor, rubber feet. That is why a natural frequency means little unless you know how the plate was mounted when it was found, and whether it was measured or simulated.
From a whisper to a shout
The same plate must resolve the few newtons by which quiet standing wavers and carry the thousands of newtons of a landing. Ask for the range of each axis and the resolution, and ask what happens beyond the range: a reading past the converter’s last step is cut flat, and the curve shows a plateau that never happened.
Twelve questions for any specification sheet
Specification sheets are written to look complete. Twelve questions make them comparable. A maker who answers all twelve in writing has nothing to hide, and the list applies to us as much as to anyone: ask us the same twelve.
| Ask | Why it matters |
|---|---|
| 1. Which components are measured, and which calculated? | “Six components” can mean six measured, or five measured and one worked out from an assumption. A calculated number is only as good as its assumption. |
| 2. The range of each axis, and the safe overload | Vertical, horizontal and moment ranges differ. A landing on one foot can load one sensor far more than the plate’s total suggests. |
| 3. Crosstalk between axes, measured, in per cent | The leak from the large vertical push into the small horizontal ones. |
| 4. Natural frequency, and how it was found | Measured or simulated, bolted down or standing on a floor. Installed plates ring lower. |
| 5. Centre of pressure accuracy, and where on the plate | Errors grow towards the edges and at low loads. In one study of crystal plates, errors under 1,600 N ranged from −20 to +20 mm across the plate (Bobbert and Schamhardt 1990), and tests with one point of contact overstate the errors under two feet (Middleton et al. 1999). |
| 6. Samples per second with all your plates running | A rate quoted for one plate can drop when several share one link. |
| 7. One clock, and synchronisation with cameras | Plates on separate clocks drift apart. Ask for a shared clock, sync in and out, or analog outputs. |
| 8. Drift and zeroing | How long a steady recording can run before the zero moves, and when you must reset it. |
| 9. Linearity and hysteresis: of the plate, or of a sensor? | A load cell’s data sheet is not a test of the finished plate. |
| 10. Calibration: method, certificate, interval | Who checks the plate, how often, at what cost, and what the guarantee covers in between. |
| 11. Raw data and file formats | Every sample of every channel, as CSV and C3D, without a paid plan. |
| 12. Size, weight, height and mounting | A plate a few centimetres high stands on any rigid floor; deeper plates need a pit or ramps. |
How often a plate should sample
A plate writes its readings down at instants, so it must write often enough to catch the fastest change in the push. Sampling theory sets the floor: more than twice the highest frequency in the signal (Shannon 1949), with a filter in front, so that faster vibrations cannot fold back into the curve as false slow ones.
The research gives the size of the stakes. In countermovement jumps, power, force and velocity measures moved by −1.8 to +1.3 % when 500 samples a second were cut to 200, and by −11.4 to +6.5 % at 50 (Hori et al. 2009). Jump height by the impulse method came out up to 4.4 % low at rates below 1,080 a second (Street et al. 2001). Landings, impacts and sprint contacts are the fastest movements; quiet standing is the slowest. Choose the rate for the fastest movement you will record, and check that it holds with all your plates running.
One clock matters as much as speed. Two plates, or a plate and a camera, that sample on separate clocks drift apart, and every millisecond of drift is a millisecond of error in every timing between them.
Portable, or set into the floor
Laboratory plates have traditionally been set flush into a pit on a concrete foundation. The floor adds stiffness, nothing trips anyone, and a walkway can hide the plates from the person walking over them. The price is building work and a fixed place.
Portable plates stand on the floor. They move between rooms and sites and set up in minutes, but they add an edge to step onto, need a flat and rigid floor and tidy cables, and ring lower on a soft floor than bolted down. Most applied work, from jump testing to standing and rehabilitation exercises led by a practitioner, suits portable plates. Gait with natural walking benefits from plates flush with the floor, or from ramps and a walkway built around portable ones.
Plates can also go under a treadmill, with care: the treadmill adds mass and lowers the natural frequency, and its motor and belt add vibration. On one force treadmill, the sideways push and the twist were too noisy to use while the vertical and forward-back pushes were recorded accurately (Kram et al. 1998).
Checking a plate yourself
A plate earns trust by passing checks anyone can run in a few minutes, and it should pass them again every time it is moved.
- Empty. Zero the plate with nothing on it and record ten seconds: every channel should sit near zero and stay there.
- Known weight. Put a known mass at the middle, then near each corner. The vertical push should match it, and the centre of pressure should land where you put the mass, checked with a ruler.
- Standing still. Stand on the plate for a minute. The horizontal pushes should stay near zero and the vertical near your weight, without creeping.
- A known sideways pull. Pull along the top with a spring balance, or with a weight over a pulley. The horizontal reading should match, and the vertical should not move.
- Two plates. Put the same mass on each in turn. They should agree.
Engineers do the same with more rigour, using known loads and the calibration matrix (Hall et al. 1996; Collins et al. 2009). If a check fails, look at the floor and the cables before you suspect the plate.
What a force plate cannot tell you
A plate measures what the floor did to the person, not how the person did it. It cannot say which muscles worked or which joint produced the push; that needs motion data and a model as well. Two feet on one plate merge into one push and one place, between the feet. And it records numbers, not reasons: the meaning comes from the person who chose the test and reads the result.
Movetrics systems measure forces and moments, calculate metrics and display them, for sport, research, education, and practitioner-led training and rehabilitation. They are not medical devices. They do not diagnose, treat, monitor or predict any disease or condition, and their results do not replace professional judgement.
What a 3D force plate costs
From about €10,000 for a pair of portable 3D plates to €30,000 to €40,000 or more for a pair of laboratory plates with amplifiers and acquisition, before any building work. Vertical-only plates cost less, bought or on subscription. Our force plate cost guide has the ranges by type, the costs that are easy to miss and a calculator; our own prices are on the prices page.
Questions people ask
Is a force platform the same as a force plate?
Yes. “Force platform” is more common in research papers and “force plate” in sport and clinics; both name the same instrument.
Is a 3D force plate the same as a six-axis force plate?
“3D” refers to the three directions of the push. “Six-axis” or “six-component” adds the three moments. Most 3D plates measure all six; some measure five and calculate the sixth. Ask which.
Do I need a 3D force plate for jump testing?
Not for jump height and most vertical jump metrics, which come from the vertical push. A 3D plate earns its place when you also care about landing direction, braking, cutting, turning, gait or balance moments.
How many force plates do I need?
One per foot whenever left and right matter: two for jumps and standing tests. Gait needs enough plates in a walkway for whole steps to land cleanly on them, or a treadmill on plates. Every plate should share one clock.
How much force goes through the body when walking, running and cutting?
In a walking step the vertical push peaks at about 1 to 1.5 body weights, rising with speed; in running at about 2 to 3 (Nilsson and Thorstensson 1989). In the cut in the live view above, the planted foot took close to 2 body weights vertically, 0.80 backwards and 0.59 sideways.
Is a portable 3D force plate accurate enough for research?
Being portable decides nothing by itself; the numbers do. Ask the twelve questions above, check the plate with known loads where it will stand, and report sampling rate, filtering and calibration in your methods.
Can force plates be synchronised with motion capture?
Yes, when they share a clock or a sync signal: sync in and out, analog outputs recorded by the camera system, or a common trigger. Ask which of these a plate offers before you plan a combined setup.
What file formats do force plates export?
CSV, which any software opens, and C3D, the biomechanics format that keeps plate geometry with the channels. Check that raw data exports without a paid plan. You can open both in our free Analyzer.
Can force plates go under a treadmill?
Yes, with limits: the treadmill lowers the natural frequency and adds vibration, and the sideways push and the twist are the hardest to measure cleanly through a belt.
How often should a force plate be calibrated?
Run the quick checks above whenever the plate is moved, and follow the maker’s interval for formal recalibration. Ours are recalibrated every two years with the TRU Check, which also renews their guarantee.
Our 3D force plates
F1-3D
All six components measured with strain-gauge load cells. 600 × 350 × 30 mm, 20 kg, 8 mm steel top. 2,000 samples a second per plate with one or two plates on the FDT (Force Data Terminal), one clock, Sync In and Sync Out, 16 analog outputs. Raw data as CSV and C3D, always.
F1-3D Dual: €14,990Explore the F1-3DF1-3D S
Five components measured and Mz calculated; six measured on request. 400 × 280 × 30 mm, 10 kg. Two join into one 40 × 56 cm platform. The same FDT, clock and raw data.
F1-3D S Dual: €9,990Explore the F1-3D SFor businesses, excl. VAT and delivery. Setup under 60 seconds from a saved layout. Make your offer · All specifications · Prices
Teaching and citing
The recordings in the live view are open research data under CC BY 4.0. Download each one with the button under the view and credit its original authors, as the file header does. To cite this page: Movetrics. 3D force plates, explained with real data. movetrics.com/3d-force-plate/
Sources
- Bobbert & Schamhardt (1990). Accuracy of determining the point of force application with piezoelectric force plates. Journal of Biomechanics 23(7):705-710. doi:10.1016/0021-9290(90)90169-4
- Bundle, Powell & Ryan (2015). Design and testing of a high-speed treadmill to measure ground reaction forces at the limit of human gait. Medical Engineering & Physics 37(9):892-897. doi:10.1016/j.medengphy.2015.04.009
- Collins, Adamczyk, Ferris & Kuo (2009). A simple method for calibrating force plates and force treadmills using an instrumented pole. Gait & Posture 29(1):59-64. doi:10.1016/j.gaitpost.2008.06.010
- Dos’Santos, Thomas, Comfort & Jones (2018). The effect of angle and velocity on change of direction biomechanics: an angle-velocity trade-off. Sports Medicine 48(10):2235-2253. doi:10.1007/s40279-018-0968-3
- Elftman (1938). The measurement of the external force in walking. Science 88(2276):152-153. doi:10.1126/science.88.2276.152
- Fukuchi, Fukuchi & Duarte (2018). A public dataset of overground and treadmill walking kinematics and kinetics in healthy individuals. PeerJ 6:e4640. doi:10.7717/peerj.4640. Data: doi:10.6084/m9.figshare.5722711, CC BY 4.0
- Hall et al. (1996). Static in situ calibration of force plates. Journal of Biomechanics 29(5):659-665. doi:10.1016/0021-9290(95)00109-3
- Holden & Cavanagh (1991). The free moment of ground reaction in distance running and its changes with pronation. Journal of Biomechanics 24(10):887-897. doi:10.1016/0021-9290(91)90167-l
- Hori et al. (2009). Reliability of performance measurements derived from ground reaction force data during countermovement jump and the influence of sampling frequency. Journal of Strength and Conditioning Research 23(3):874-882. doi:10.1519/jsc.0b013e3181a00ca2
- Kram, Griffin, Donelan & Chang (1998). Force treadmill for measuring vertical and horizontal ground reaction forces. Journal of Applied Physiology 85(2):764-769. doi:10.1152/jappl.1998.85.2.764
- Lentink, Haselsteiner & Ingersoll (2015). In vivo recording of aerodynamic force with an aerodynamic force platform: from drones to birds. Journal of the Royal Society Interface 12(104):20141283. doi:10.1098/rsif.2014.1283
- Li et al. (2001). Free vertical moments and transverse forces in human walking and their role in relation to arm-swing. Journal of Experimental Biology 204(1):47-58. doi:10.1242/jeb.204.1.47
- Middleton, Sinclair & Patton (1999). Accuracy of centre of pressure measurement using a piezoelectric force platform. Clinical Biomechanics 14(5):357-360. doi:10.1016/s0268-0033(98)00079-5
- Morin, Edouard & Samozino (2011). Technical ability of force application as a determinant factor of sprint performance. Medicine & Science in Sports & Exercise 43(9):1680-1688. doi:10.1249/MSS.0b013e318216ea37
- Nilsson & Thorstensson (1989). Ground reaction forces at different speeds of human walking and running. Acta Physiologica Scandinavica 136(2):217-227. doi:10.1111/j.1748-1716.1989.tb08655.x
- Scherpereel et al. (2023). A human lower-limb biomechanics and wearable sensors dataset during cyclic and non-cyclic activities. Scientific Data 10:924. doi:10.1038/s41597-023-02840-6. Data: doi:10.35090/gatech/70296, CC BY 4.0
- Shannon (1949). Communication in the presence of noise. Proceedings of the IRE 37(1):10-21. doi:10.1109/JRPROC.1949.232969
- Street et al. (2001). Sources of error in determining countermovement jump height with the impulse method. Journal of Applied Biomechanics 17(1):43-54. doi:10.1123/jab.17.1.43

