Research and laboratories
Force plates for research: the answers your lab needs before it buys
Researchers ask the same questions before they buy a force plate, and they are the right questions: what is measured and what is calculated, how fast, against which clock, into which software, calibrated how, and what nobody has measured yet. This page answers all of them for our plates, including the parts that are still open.
In short
- Six components measured on the F1-3D, 600 × 350 × 30 mm; five on the F1-3D S, 400 × 280 × 30 mm, with Mz calculated.
- 2,000 samples a second per plate with one or two plates, 1,000 with three or more, every plate on one clock with 0.1 ms timestamps.
- Into your lab through 16 analog outputs (±10 V), Sync In and Sync Out (3.3 V), C3D and CSV files, an open protocol and an SDK for Python, MATLAB and Lab Streaming Layer.
- A calibration certificate for each plate, a TRU Check every two years, and up to 10 years of guarantee on the plates.
- Start with one plate: an F1-3D with the FDT costs €7,745, and each plate added later €7,245.
Twelve questions, answered for our plates
Our 3D force plate guide lists twelve questions to put to any maker. Here are our answers, including the ones we cannot give yet.
| Question | F1-3D | F1-3D S |
|---|---|---|
| 1. Measured or calculated? | All six measured: Fx, Fy, Fz, Mx, My, Mz | Five measured; Mz calculated from Fx. Six measured on request |
| 2. Range and safe overload | Fz 8,000 N, safe 12,000 N. Fx, Fy ±2,000 N, safe ±3,000 N. Mx ±600 N·m, My ±400 N·m, Mz ±300 N·m | Fz 4,000 N, safe 6,000 N. Fx, Fy ±1,000 N. Mx ±200 N·m, My ±140 N·m |
| 3. Crosstalk | Not published yet: we publish it once our bench measurement is complete. Until then, ask us where it stands | As the F1-3D |
| 4. Natural frequency | 509 Hz, the first mode of the plate’s own structure rigidly mounted, simulated, not measured. A floor that gives lowers it | Not published |
| 5. Centre of pressure | 5 mm maximum error, reported over ±160 × ±250 mm from the centre | 5 mm maximum error |
| 6. Samples per second | 2,000 per plate with one or two plates, 1,000 with three or more | The same |
| 7. Clock and sync | One clock for every plate on an FDT, timestamps in 0.1 ms steps; Sync In and Sync Out, 3.3 V; 16 analog outputs for plates 1 and 2 | The same |
| 8. Drift and zero | Strain-gauge load cells, which hold a steady push without the reading sinking. Zero taken at start and on tare | The same |
| 9. Linearity | Load cells below 1 % non-linearity, a sensor specification, not a test of the finished plate | The same |
| 10. Calibration | Certificate per plate with serial, method, results and calibration matrix; TRU Check every two years | The same |
| 11. Raw data | Every sample as CSV and C3D, always, without a paid plan; open protocol and SDK under Apache-2.0 | The same |
| 12. Size, weight, mounting | 600 × 350 × 30 mm, 20 kg, 8 mm steel top; portable on a rigid floor, or flush in a recess frame | 400 × 280 × 30 mm, 10 kg; two join into one 40 × 56 cm platform |
Recording with motion capture, EMG and cameras
There are three ways to put our force data on the same time base as cameras, motion capture and EMG. Which fits best depends on the software you record with, and we help you choose. Here is how each works, and what has been measured on real hardware so far.
| Route | How it works | Status today |
|---|---|---|
| Analog outputs | Each plate’s three forces, three moments and centre of pressure on 16 outputs of ±10 V (plates 1 and 2, DB-25), recorded by your motion capture or EMG system on its own clock next to its other channels. We provide the calibration matrix and plate geometry your software asks for. | Available today Up to 500 updates a second per plate, within 1 % of the digital values. The forces arrive about 16 to 19 ms late at Studio’s settings, 11 to 13 ms with the FDT’s low-pass off (computed): measure it once with a tap test and subtract it. Planned: analog without the low-pass, and the Sync In trigger sent out with the analog forces so the delay cancels. |
| Digital, with Lab Streaming Layer | The SDK streams every sample with the FDT’s own timestamp, mapped onto the Lab Streaming Layer clock, so one recorder writes force, EMG, EEG and markers into one file. | Not yet timed on real hardware The host software is done and tested end to end with the simulator. Not yet run with a real FDT and a lab recorder. |
| Sync In and Sync Out | 3.5 mm jacks at 3.3 V: the FDT can start on a pulse, or send pulses; every edge is time-stamped on the FDT clock, so its delay to the computer drops out. | Not yet timed on real hardware The jacks are on every FDT. The firmware modes that drive them run in simulation; their timing has not yet been measured on a real FDT. Ask us before you plan a study on them. |
Files. Movetrics Studio writes CSV and C3D for every exam. The C3D carries the force platform parameters motion analysis software reads: corners, origin and channels in newtons and newton metres. The CSV carries the FDT’s own timestamps; use it when you align force with other devices, because the C3D puts samples on an even grid. Your own code. The protocol is open and the SDK, under Apache-2.0, reads the FDT from Python, MATLAB and TypeScript. Everything here is documented in detail for engineers on developers.movetrics.com, with what was measured and what was simulated.
For millisecond timing, such as force onset against EMG onset, record with the low-pass off and tell us your setup: we confirm the route and the delay for your equipment before you start.
What to put in your methods section
A reviewer will ask how the force data were sampled, filtered and zeroed. These are the facts to report, and the choices that are yours.
- Sampling. 2,000 samples a second per plate with one or two plates on the FDT, 1,000 with three or more. Over USB the FDT’s frame counters showed no frame lost at 2,000 a second.
- Filtering. The FDT applies a 50 Hz low-pass filter by default. Through the SDK you can switch it off and filter afterwards with your own method, which is what timing studies should do, because every filter delays the signal.
- Resolution. Each sample carries forces in whole newtons and moments in whole newton metres. At a body weight of 700 N, one newton metre moves the centre of pressure by 1.4 mm, so average over many samples when sub-millimetre detail matters, as it does in quiet-stance sway.
- Zero. The FDT takes its zero when it starts and when you tare. Keep the plates empty at that moment, and record a few seconds of empty plates at the start of a session.
- Axes. Origin at the centre of the top, x along the 350 mm side, y along the 600 mm side, z up; moments about a point 30 mm below the top. Two-plate files place the plates side by side, plate 1 on the left. Before you combine our files with another system’s, check axes, signs and the moment origin: our units and axes page lists them.
- Calibration. Name the plate serial numbers, the date of the calibration certificate, and the check with known weights you ran in your lab.
Calibration, checks and service
Every plate leaves us calibrated, with its own certificate: serial number, method, results and calibration matrix. A plate stays trustworthy only if it is checked where it stands, so the five quick checks in our 3D force plate guide take a few minutes with known weights and belong at the start of any study.
We recalibrate every two years, and after an overload, a drop or a move to a new site. The TRU Check tests, recalibrates and services the system and gives you a new certificate. It costs €590 for the first plate and €300 for each further plate, excl. VAT, plus collection and return. Each passed TRU Check renews the guarantee on the plates for two more years, up to 10 years; the FDT has two years. The guarantee terms are binding.
Nothing else needs servicing. The software keeps working after its 24 months of updates, security updates stay free, and measuring and exporting raw data never need a paid plan.
Buying as a university or institute
- Start small, grow on one clock. One plate with the FDT, then more plates on the same FDT at the same price per plate, from next year’s budget or the next grant.
- A quote for your purchasing office within one working day, binding for 30 days, with everything a procurement file asks for: what is included, delivery, and our company and VAT details.
- University programme. Public universities and research institutes: ask us about it when you request your quote.
- The Measurement Guarantee. When you order, we record what you want to measure. If the system does not measure it, tell us within 30 days of setup; if we cannot put it right within 30 days, you may withdraw and we take the system back and refund you. The Terms of Sale are binding, and the German text prevails.
- Setup and training. Remote setup and two hours of online training come with every system; on-site installation and team training in the EU cost €1,200, travel included.
- Your data stay yours. Recordings stay on your computer unless you upload them to Movetrics Cloud, which is optional; we get no rights to your data.
- Who builds it. Invented, designed, built and assembled in Germany, by Nur Engineering GmbH in Duisburg, CE marked. Support in English, German, Italian and Arabic.
How many plates for your study
One plate under both feet measures everything the whole body does: jump height, take-off velocity, power, force production over a series of efforts, and the centre of pressure shift before a first step. A second plate tells the two legs apart, and walking needs one plate for each step you want whole. Our guide One force plate or two? has a table by test, from anticipatory postural adjustments to sprint starts, and a real jump recorded on two plates.
Our plates for research
Two plates, one terminal, the same software. Both measure in all three directions, stand 30 mm high and connect to the FDT.
F1-3D
All six components measured with strain-gauge load cells. 600 × 350 × 30 mm, 20 kg, 8 mm steel top. 2,000 samples a second per plate with one or two plates on the FDT (Force Data Terminal), one clock, Sync In and Sync Out, 16 analog outputs. Raw data as CSV and C3D, always.
F1-3D Dual: €14,990Explore the F1-3DF1-3D S
Five components measured and Mz calculated; six measured on request. 400 × 280 × 30 mm, 10 kg. Two join into one 40 × 56 cm platform. The same FDT, clock and raw data.
F1-3D S Dual: €9,990Explore the F1-3D SFor businesses, excl. VAT and delivery. Setup under 60 seconds from a saved layout. One F1-3D with the FDT: €7,745; one F1-3D S with the FDT: €5,245; each further plate €7,245 or €4,745. Make your offer · All specifications · Prices
Questions researchers ask
Can I buy a single 3D force plate rather than a pair?
Yes. One F1-3D with the FDT, cables, Movetrics Studio and the Movetrics app costs €7,745, excl. VAT and delivery. A second F1-3D joins the same FDT later for €7,245, so the two cost what a Dual costs bought at once.
Do you offer an academic discount?
Public universities and research institutes: ask us about our university programme when you request your quote.
Can your force plates be synchronised with motion capture?
Yes: through the 16 analog outputs recorded by the motion capture system, through Sync In and Sync Out, or digitally through the SDK and Lab Streaming Layer. The analog route is available today; the timing of the sync modes and of Lab Streaming Layer has not yet been measured on a real FDT, so we confirm the route for your setup first.
Can I record EMG and force together?
Yes. An EMG amplifier’s auxiliary inputs can record the analog outputs, or EMG and force can share one Lab Streaming Layer recording. Tell us which EMG system you use and we confirm the setup.
Do you supply the calibration matrix?
Yes. Each plate’s certificate carries it, and for the analog route we provide the matrix and plate geometry in the form your software asks for.
Do the plates export C3D?
Yes. Movetrics Studio writes C3D with force platform parameters and CSV with every sample, for every exam, without a paid plan.
How often must the plates be recalibrated, and what does it cost?
Every two years, and after an overload, a drop or a move. The TRU Check costs €590 for the first plate and €300 for each further plate, excl. VAT, plus collection and return, and renews the guarantee on the plates.
Is 2,000 samples a second enough?
For jumps, landings, sprint contacts and standing, yes: it is well above the frequencies in human movement, and the plate’s own structure was simulated at 509 Hz. Record unfiltered when you study timing, and filter afterwards.
Can I take the plates to another lab or outdoors?
Between labs, yes: they are 30 mm high and portable, and every move calls for the quick checks with known weights. They are made for indoor use; talk to us before you take them outdoors.
Is a Movetrics system a medical device?
No. It measures, calculates and displays. The interpretation is yours, as the researcher.
Where these answers come from
Specifications from our product sheets and our specifications page; timing, files and test status from the developer documentation, which marks every statement as measured, computed or simulated. Prices for businesses, excl. VAT and delivery. Where we have not measured something yet, we say so.
Movetrics systems measure forces and moments, calculate metrics and display them, for sport, research, education, and practitioner-led training and rehabilitation. They are not medical devices. They do not diagnose, treat, monitor or predict any disease or condition, and their results do not replace professional judgement.